Hydrant outlet and valve for the underground form hydrant and valves with the stand article kind hydrant should be Positioned as close to the bottom amount as feasible. The very best with the outlet or spindle of your valve must be in a depth not exceeding 0.3 m.

請注意:務必確保已選取的區域來自正確的螢幕截圖(螢幕內),否則裝置將永遠顯示黑色。若您從外接螢幕選擇區域,且螢幕已從桌上型電腦或筆記型電腦拔除,請在套用具有同步辨色的燈效設定檔前,重新選擇自訂區域。

华硕提供您此非华硕所制造之产品的相关信息仅为参考之用,请直接洽询该厂商以了解产品详情,华硕与此信息或服务无涉。

In case of industries of high hazard classification (Gr G-3, H and J), the hydrants really should be installed at each 30 m aside together making line along with the hydrant outlet need to be one or double hydrant with provision of landing valves. For reasonable hazard (Gr G-2) where The one hydrant is use, it should be installed at every 45 m aside. In case of any portion that has many dangers, the pertinent part must be lined according to the provision specified for better hazard.

以上部分資訊可能部分或全部引用於華碩外部網站,請以標註之資料來源為準,如有疑問請直接洽詢該來源,華碩與此資訊或服務無涉。

If anyone behaves inappropriately, make use of the report button to inform our moderation workforce. Reports are reviewed immediately to keep up a secure and respectful Group for all customers.

Isolating (Slice off) valves should be totally overhauled yearly to get rid of sludge along with other international subject gathered in valve seating.

Regular manhole addresses of Forged iron or bolstered concrete should not be used to protect underground hydrants or even the valves on the stand write-up kind hydrants. They ome88 need to be protected only by hinge Forged iron handles as specified in IS 3950: 1979 with letters ‘FH’ embossed on them.

Screening of stress and output in ome88 various parts included with the hydrant method need to be carried, no less than every single quarter. Hydrant mains ought to be analyzed Together with the pump delivering at its utmost stress with many of the ome88 hydrants outlet closed and thereafter, with a minimum of a few adjacent hydrants opened to find out which the hydrant produce the minimum amount output of 1 a hundred twenty five litres for every minute in a minimum strain of 5.

此篇知識可能不適用於所有同類型/系列的產品,部分畫面選項或操作步驟可能會因為軟體版本的不同而有差異。

In cold climates where frost is likely to get skilled, the hydrants needs to be fitted with ideal suggests for draining from the drinking water trapped in your body with the hydrant among the valve and also the outlet.

All sluice valves should really conform to IS 780: 1984 and enclosed in thoroughly constructed floor packing containers to be able to allow for for damaged joints staying conveniently re-built. Valve wheels must have an arrow head engraved or Solid thereon exhibiting route for turning ‘Open’ and ‘near’.

The file of all this kind of inspections need to be managed and remedial motion for any defects noticed must be ome88 instantly taken on precedence basis.

The valve spindles really should be checked and any indications of excessive put on like leakage during the gland got rectified. If a Untrue spindle is fitted, it should be checked that it's in situation and securely preset.

The fireplace hydrant mains should usually be laid in rings or crosslinked rings, which ome88 is, every one of the mains really should be interconnected.